
Vol. 13, No. 3, 2004
Free Abstract
Article (References)
Article (PDF 131 KB)
Original Paper
The Impact of Nurse Understaffing on the Transmission of Hepatitis C Virus in a Hospital-Based Hemodialysis Unit
Anil Kumar Saxenaa, B.R. Panhotrab
Departments of aNephrology and bMicrobiology and Infection Control, King Fahad Hospital and Tertiary Care Center, Hofuf, Saudi Arabia
Address of Corresponding Author
Med Princ Pract 2004;13:129-135 (DOI: 10.1159/000076951)
Key Words
- Nurse understaffing
- Hemodialysis
- Hepatitis C virus
- Nosocomial transmission
Abstract
Objective: To determine the impact of nurse understaffing on the transmission of hepatitis C virus (HCV) infection in a large hospital-based hemodialysis (HD) unit with a high HCV prevalence. Subjects and Methods: The records of 198 patients (107 males and 91 females) with end-stage renal disease enrolled on long-term HD at King Fahad Hospital and Tertiary Care Center, Hofuf, Saudi Arabia, from August 1995 to August 2000, were retrospectively reviewed. The patients were assigned to HD groups of varying patient-to-nurse (P/N) ratios: group I, 2:1; group II, 3:1, and group III, 4:1. HCV prevalence, seroconversion rates, history of blood transfusion and dialysis age (time span since the initiation of the HD treatment) were recorded and compared. Results: The overall HCV prevalence and seroconversion rate per year were 43.4 and 8.6%, respectively. Group I had the lowest HCV prevalence and annual seroconversion rate (26.8%; 5.3%), followed by group II (43.6%; 8.7%); group III had the highest HCV prevalence and seroconversion rate (71.8%; 14.4%). Anti-HCV positivity was associated with a higher dialysis age. Conclusion: The finding that the patients in the groups with the relatively higher P/N ratio had the significantly higher HCV prevalence and seroconversion rates per year indicates that understaffing is likely to play a major role in the transmission of HCV in HD units, and we suggest that improved staffing may be helpful in reducing the HCV transmission in such dialysis units. Copyright © 2004 S. Karger AG, Basel
Author Contacts
Anil K. Saxena Division of Nephrology King Fahad Hospital and Tertiary Care Center Hofuf, Al-Hasa 31982 (Saudi Arabia) Tel. +966 3 5756125, Fax +966 3 5754094, E-Mail dranil_31982@yahoo.com
Article Information
Received: October 13, 2002
Revised: April 21, 2003
Number of Print Pages : 7
Number of Figures : 3, Number of Tables : 3, Number of References : 20 |
|

|

For non-native English speakers and international authors who would like assistance with their writing before submission, we suggest American Journal Experts for their scientific editing service. |
|
|